Our Best

DATA CENTERS

Los Angeles, California Data Center

Location: Los Angeles, California
POP for CDN media including AR and VR

Upload and Customer Direct Pick Up for Rendering Projects

Virtual Reality North America Distribution and DR services

For more information: VRinfo@xconnectdc.com

Additional sites coming soon.
Need service in an exact area…? Let us help you get the solution you need.
For informational purposes only. XconnectDC does not guarantee the information set forth above and it may be changed without notice.

In Development!

Ohio Data Center

Location: Ohio Data Center Size: 75,000 Square Feet

On-Net Products
IP Transit Ethernet Transport Services
Standard Rack Configuration
42U Cabinets (Type: APC AR3100) Power extra; (1) 110v/20 amp or (2) 110v/20A standard
Carrier Availability – In Data Center
AT&T
Facilities
480v 3-phase utility feed – 4,000 amps 5000 sq. feet of raised floor data center space in Akron Custom Cages available WIFI Available
UPS Systems
(6) UPS Units – 500kVA each (Powerware) “A+B” system – 3 UPS Units in “parallel” each
Generator Systems
(3) Caterpillar Diesel Generators – 1500kW each Generators work in “parallel” for redundancy All (3) units share 6,000 gallon diesel fuel tank
HVAC
Chilled Water system; (3) Trane chillers; 320-ton each Chillers work in “redundant” setup; auto-tested weekly (6) 40-ton chilled water Liebert HVAC units in DC1 (3) chilled water Air Handling Units in DC2 40,000-gallon underground storage water tank
Security
C*CURE Card-Reader Access Control System (16) card readers total at all essential access points Entrance into actual data center requires HID card swipe and unique pin code for access (27) cameras with remote monitoring and recording capabilities – recording to local DVR system
Electrical
(3) Benjamin Electric Automatic Transfer Switches (16) PDI PDUs and (4) Liebert PDUs in both data centers
Fire Systems
Fire suppression and detection system consists of heat detectors, smoke heads, preaction sprinkler system, and separate gas-tank systems in each data center room (4) FM-200 tanks in DC1; (112) Inergen tanks in DC2 Vesda air sampling smoke detection system
Battery Room
(240) “wet-cell” UPS batteries (C&D) “sealed” UPS batteries (Powerware)
Additional sites coming soon. Need service in an exact area…? Let us help you get the solution you need. For informational purposes only. XconnectDC does not guarantee the information set forth above and it may be changed without notice.

In Development!

New Jersey Data Center

Location: New Jersey Area, USA Size: 120000 Square Feet

On-Net Products
IP Transit Ethernet Transport Services
Standard Rack Configuration
42U Cabinets (Type: APC AR3100) Power extra; (1) 110v/20 amp or (2) 110v/20A standard
Carrier Availability – In Data Center
AT&T
Facilities
480v 3-phase utility feed – 4,000 amps 4000 sq. feet of raised floor data center space in DC1 10,000 sq. feet of raised floor data center space in DC2 Custom Cages available WIFI Available
UPS Systems
(6) UPS Units – 500kVA each (Powerware) “A+B” system – 3 UPS Units in “parallel” each
Generator Systems
(3) Caterpillar Diesel Generators – 1500kW each Generators work in “parallel” for redundancy All (3) units share 6,000 gallon diesel fuel tank
HVAC
Chilled Water system; (3) Trane chillers; 320-ton each Chillers work in “redundant” setup; auto-tested weekly (6) 40-ton chilled water Liebert HVAC units in DC1 (3) chilled water Air Handling Units in DC2 40,000-gallon underground storage water tank
Security
C*CURE Card-Reader Access Control System (16) card readers total at all essential access points Entrance into actual data center requires HID card swipe and unique pin code for access (27) cameras with remote monitoring and recording capabilities – recording to local DVR system
Electrical
(3) Benjamin Electric Automatic Transfer Switches (16) PDI PDUs and (4) Liebert PDUs in both data centers
Fire Systems
Fire suppression and detection system consists of heat detectors, smoke heads, preaction sprinkler system, and separate gas-tank systems in each data center room (4) FM-200 tanks in DC1; (112) Inergen tanks in DC2 Vesda air sampling smoke detection system
Battery Room
(240) “wet-cell” UPS batteries (C&D) “sealed” UPS batteries (Powerware)
Additional sites coming soon. Need service in an exact area…? Let us help you get the solution you need. For informational purposes only. XconnectDC does not guarantee the information set forth above and it may be changed without notice.